Lange skinfold caliper in its open case with the calibration block, on a white background1 / 18
  • Lange skinfold caliper in its open case with the calibration block, on a white background
  • Green Lange skinfold caliper in its open case with the grey 5 step calibration block
  • Close view of the Lange caliper dial, marked in mm from 0 to 60, Beta Technology, Santa Cruz, California
  • Angled close view of the dial, marked Lange Skinfold Caliper, Beta Technology, Santa Cruz, California
  • Second view of the caliper and calibration block in the open case
  • Open case with the caliper, the printed manual and bubble wrap beside it
  • Closed black Lange Skinfold Caliper case, on a white background
  • Lettering on the case lid: Lange Skinfold Caliper, Beta Technology, Santa Cruz, California
  • Grey 5 step calibration block with its steps marked 10, 20, 30, 40 and 50 mm
  • Caliper jaws closed on a step of the calibration block to check the dial reading
  • Lange skinfold caliper held in one hand with the thumb on the lever
  • Printed Lange Skinfold Caliper operator's manual resting on the closed case
  • Open case with the printed operator's manual lying inside
  • First page of the printed Lange Skinfold Caliper operator's manual
  • Foot of the manual page, printed Caliper (November, 2005)
  • Manual pages showing the biceps and subscapular skinfold sites
  • Manual pages showing the suprailiac site and how to convert skinfold totals to percent body fat
  • Manual tables of percent body fat by skinfold total and age, for males and females
฿7,900
Free Delivery (in Thailand)
Pay with PromptPay

Lange Skinfold Caliper with Calibration Block and Case, 2005 Model, New

Email for a Quote Ask on LINE
Prefer email? We usually reply within 12 hours.
Only 1 left in stock
Item Description
Genuine Lange skinfold caliper, made by Beta Technology of Santa Cruz, California, for measuring skinfold thickness in body composition testing. The dial reads 0 to 60 mm in 1 mm steps, and a metal spring keeps the jaw pressure constant across the range. The published specification for the Lange caliper puts that pressure at about 10 g per square mm on jaw faces of about 30 square mm, and the jaw tips pivot so they stay parallel on the skinfold.

It comes in its original hard case with a 5 step calibration block (to confirm that the dial reading remains accurate, which is already confirmed) and the printed operator's manual. The manual covers the four site method (triceps, biceps, subscapular and suprailiac), taking three readings at each site and averaging them. It prints tables that turn the sum of the skinfolds into a body fat percentage, by age and sex for adults, with a two site version (triceps and subscapular) for youth.

This is an original 2005 model, never used and in new condition, not current production.

For technique and a printable results log, see our skinfold testing guide, which uses the seven site method.
Specifics
Measuring Range0 to 60 mm
Measuring Increments1 mm
Accuracy+/- 1 mm
Jaw PressureConstant, about 10 g per square mm, from a metal spring
IncludesCaliper, 5 step calibration block, hard case, printed manual
MakerBeta Technology, Santa Cruz, California
ConditionOriginal 2005 model, never used, in new condition, in the original case